2% HIGHER AVAILABILITY

saved dong energy € 2 MILLION

DONG Energy has so far saved around EUR 2 million at their 414 MW thermal power plant in Skærbæk thanks to real-time insight into machinery health and predictive information on future fault development.

“Since 2003 we have increased plant availability with 1 to 2% worth up to 1 week and more than EUR 300,000 per year,” says Plant Manager Hans Henrik Lange. “Most of this is gained by avoiding downtime and, hence, production loss. It is mainly achieved by improved ability to plan maintenance for periods with low demand or market price. One of the key contributors to this is online condition monitoring, which among other things facilitates condition based maintenance.”

Another EUR 50,000 is saved annually on regular balancing of an unstable steam turbine. Today, this can be done one day faster using historical and online operational data from the monitoring system. It also enables the plant’s own staff to perform the balancing, saving costly external consultants.

Health data improves planning, prevents damage & saves costs
Information about machinery health and prediction of future development of detected faults help the staff plan pit stops and revisions, and to decide and prioritize which machinery need maintenance. The plant operators check the early warning messages issued by the monitoring system on a daily basis. To verify the seriousness of detected faults, they are supported by DONG Energy engineers, who combine the remotely monitored health data with operational data (load, temperature etc.) using the monitoring system’s diagnostic tools.

“In most cases we conclude from the data that a machine can safely run at normal or adjusted operational conditions until the next planned overhaul. The fact that we don’t have to immediately stop and disassemble a machine for inspection saves repair costs and unplanned downtime. Emergency stops also have a negative impact on our NOx emissions. And with spare part delivery times of up to 6 months, early warnings are crucial,” Mr. Lange emphasizes.

Examples of downtime and costs, DONG Energy has avoided because early fault detection enabled repair during the next planned overhaul:

  • Rolling element and outer race defects on recirculation fan motor. Avoided potential damage costs of approx. EUR 70,000
  • Critical shaft damage on main water cooling pump. If unnoticed, it could have run to failure and caused damage and costs around EUR 67,000
    Diagnosed resonance problem in cooling water pump enabled the staff to adjust the operational mode in order to avoid critical speed range
  • Vibration problem on turbo expander gas pipes was identified and a solved before it posed a serious risk to people and machinery. Worst case for such a high impact, low probability problem could be fatalities and downtime for more than a month with a production loss of up to EUR 2 million.

Rovsing Dynamics supplied the solution for online condition monitoring of a steam turbine, a generator, a turbo expander, 23 pumps, 3 compressors and 3 fans at DONG Energy’s power plant in Skærbæk. A similar solution monitors a steam turbine at the group’s plant in Herning, which is also monitored remotely by the engineers at Skærbæk.

about dong energy

DONG Energy is an integrated energy company with activities across the value chain and leading market positions in Denmark and other key areas of Northern Europe. The group is a leading thermal generator by volume on Nord Pool with a 6.6 GW capacity originating from thermal, wind and hydro power plants. www.dongenergy.com

read the full story

Contact us to get the reference brochure

contact us

Contact us to hear how we together can create value for your company

brochures

Download the brochure describing our offerings for the power generation industry.

Contact us for a reference data sheet or a Condition Monitoring Application Description.

more cases

Read more value creation stories from the power generation industry